MD MEGABOND 2000 (MR 1:1) double cartridge, 50 + 400 g

    MMA Adhesive
    MR 1:1, 7 min
    50 and 400 g

    MD MEGABOND 2000 (MR 1:1) double cartridge, 50 + 400 g

    Fast-setting two-component methyl methacrylate adhesive

    MD MEGABOND two-component high-performance adhesive is the "Formula One racer" amongst high-performance adhesives. It can be used where conventional adhesives do not achieve the required strengths.

    • Excellent impact, peeling and shear strength
    • High resistance to weathering
    • Quick-fixing
    • Requires little surface preparation
    • High bond strength, optimal for plastics such as ABS
    • Fast-setting
    • Gap-filling

    MD MEGABOND 2000

    Temperature resistance: -55 °C up to 120 °C
    Mixing ratio: 1 : 1
    component A : component B
    Processing time:
    approx. 5 - 7 minutes
    Fixing time: approx. 10 - 12 minutes
    Typical handling strength: approx. 1 h

    Applications:
    For wood, metal, ceramics, stone, and a great number of plastics such as ABS, polystyrene, PVC, Perspex®, GFRP, etc. Plastics that cannot be joined with this adhesive are Teflon®, polyethylene, polypropylene, flexible PVC and polyamide (Nylon®). Bonding various materials is extremely quick and reliable.

    Storage: Cool, dry and dark. The ideal temperature is 12 - 15 °C (storage temperatures above 23 °C can damage the material).

    Please order separately:
    Mixing tubes
    for 25 g: Order no. 1551642
    for 400 g: Order no. 155168x

    Dosing gun
    for 50 g: Order no. 1551611
    for 400 g: Order no. 1539972

    MD-MEGABOND 2000 (1:1) double cartridge/ 50 g

    Marston-Domsel

    Item no.  1551451 207 in stock  (delivery time 1-2 days)

    Add to Shopping List

    9,91 
    (Base Price 198,20 € /  kg)

    Scaled Price

    • From Qty 2:  10,0%
    • From Qty 6:  15,0%
    • From Qty 12:  20,0%
    • From Qty 24:  25,0%
    • From Qty 48:  30,0%
    • From Qty 96:  35,0%
    - +

    all Prices  price incl. VAT, possibly plus shipping

    Article information

    type: ga
    language: [language]
    info3: [info3]
    filetype: [filetype]
    url: [url]
    Instructions for use
    type: si
    language: [language]
    info3: [info3]
    filetype: [filetype]
    url: [url]
    MSDS
    type: pi
    language: [language]
    info3: [info3]
    filetype: [filetype]
    url: [url]
    Product information
    type: td
    language: [language]
    info3: [info3]
    filetype: [filetype]
    url: [url]
    type:
    language: [language]
    info3: [info3]
    filetype: [filetype]
    url: [url]

    Hazards identification - MD-Megabond 2000 Activator

    Hazard components for labelling

    Methyl methacrylate
    Methacrylic acid
    Cumene hydroperoxide
    Tosyl chloride

    Signal word: Danger

    Pictograms:

    GHS02 GHS05 GHS07

    Hazard statements

    H225 Highly flammable liquid and vapour.
    H314 Causes severe skin burns and eye damage.
    H317 May cause an allergic skin reaction.
    H335 May cause respiratory irritation.
    H412 Harmful to aquatic life with long lasting effects

    Precautionary statements

    P101 If medical advice is needed, have product container or label at hand.
    P102 Keep out of reach of children.
    P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
    P271 Use only outdoors or in a well-ventilated area.
    P280 Wear protective gloves / protective clothing / eye protection / face protection.
    P301 P330 P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
    P303 P361 P353 IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water or shower.
    P305 P351 P338 IF IN EYES: Rinse continuously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing.
    P310 Immediately call a POISON CENTER or doctor / physician.
    P405 Store locked up.
    P501 Dispose of waste according to applicable legislation.

    Hazards identification - MD Megabond 2000 adhesive

    Hazard components for labelling

    Methyl methacrylate

    Signal word: Danger

    Pictograms:

    GHS02 GHS07

    Hazard statements

    H225 Highly flammable liquid and vapour.
    H315 Causes skin irritation.
    H317 May cause an allergic skin reaction.
    H335 May cause respiratory irritation.
    H412 Harmful to aquatic life with long lasting effects

    Precautionary statements

    P101 If medical advice is needed, have product container or label at hand.
    P102 Keep out of reach of children.
    P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
    P271 Use only outdoors or in a well-ventilated area.
    P280 Wear protective gloves / protective clothing / eye protection / face protection.
    P333 P313 If skin irritation or a rash occurs: Get medical advice / attention.
    P405 Store locked up.
    P501 Dispose of waste according to applicable legislation.